Industries · Mining and quarrying
Identify unusual conveyor drive behaviour and prioritise the checks
Conveyor drives, crushers, screens and dewatering pumps wear out slowly and fail fast. Each one compared with its own baseline gives the maintenance team time to plan the shutdown, without a reliability centre of your own.
What we watch
The equipment that costs most when it stops
Conveyor drives and pulleys
Motor, gearbox and pulley bearings, and misalignment.
Crushers and screens
Bearing temperature, vibration and load patterns that change with wear.
Slurry and dewatering pumps
Wear, cavitation, blockages and dry running.
Ventilation and dust extraction
Fan imbalance, bearing wear and filters loading up.
Site power and compressors
Generator fuel and cooling pumps, switchroom air conditioning, and compressors running more than demand explains.
Drive and PLC data
Current, load, run hours and trips read from the equipment already on site.
Early signs
What the models look for
Each machine is compared with its own normal running, not a generic limit, so a slow change shows up long before an alarm would.
- Bearing vibration or temperature leaving its normal band
- A drive drawing more current for the same tonnes
- A pump losing output, or running dry
- A fan vibrating more as it wears or loads up
Mine and quarry plant usually has drives and PLCs that already measure current, load and trips. Reading them is designed to be read-only, with wireless sensors added on bearings and gearboxes.
Start with a data reviewPlant networks and serial links between PLCs, drives and remote I/O, watched for a device or command that does not belong.
Questions
Mining and quarrying: common questions
We already have a vibration contractor on a route. Does this replace them?
It does not have to. A route gives an expert reading every few weeks. Continuous monitoring watches between visits and tells the analyst which machine to look at first.
What if the site has poor mobile coverage?
Alerts can go into the site’s own SCADA or historian instead of over the mobile network. Coverage is checked during scoping, before anything is fitted.
Can we start without anyone coming to site?
Yes. A data review works from a historian or drive data export, so there are no inductions, site access or new equipment on your network until the results say it is worth it.
How the monitoring works Automation services OT Security Health Check
Other industries
The same models, other sites
Energy: solar and battery sites
Solar and battery sites: inverters, strings, battery health and the cooling plant they rely on.
See what we watchWater and wastewater
Pump stations, aeration blowers, dosing pumps and bores.
See what we watchFarms and irrigation
Bore and irrigation pumps, dairies, grain fans and coolrooms.
See what we watchFood, beverage and cold storage
Refrigeration, coolrooms, glycol chillers and process pumps.
See what we watchManufacturing
Motors, gearboxes, compressed air, extraction fans and hydraulics.
See what we watchBuildings and facilities
Chillers, air handlers, cooling towers, pumps and data room cooling.
See what we watchCouncils and public facilities
Aquatic centres, pump stations, depots and public buildings.
See what we watch