Products
iON Bus Monitor: an early warning on your plant's network
- RS485
- MODBUS RTU
- MODBUS TCP
- AIR-GAPPED
- IN DEVELOPMENT
Pumps and production lines often talk over older serial cables that office security tools cannot see. iON Bus Monitoris a small air-gapped box designed to listen on those cables, learn what normal looks like, and tell you when a device or command appears that should not be there. It is in development, and these descriptions reflect our current plans.
- 0002.42703→M03 03 02 08 7F 87 A4level = 2175
- 0003.612M→0101 03 00 00 00 02 C4 0BREAD HOLDING @0000 ×2
- 0003.62701→M01 03 04 05 B6 00 3D DA C8drive = 1462, 61
- 0004.812M→0202 03 00 10 00 02 C5 FDREAD HOLDING @0010 ×2
- 0004.82702→M02 03 04 01 41 00 07 D9 19flow = 321, 7
- 0006.012M→0303 03 00 00 00 01 85 E8READ HOLDING @0000
- 0006.02703→M03 03 02 08 5C C6 7Dlevel = 2140
- 0007.231??→0202 10 00 20 00 01 02 00 FF F5 80WRITE MULTIPLE · not in baseline
- 0008.412M→0202 03 00 10 00 02 C5 FDREAD HOLDING @0010 ×2
- 0008.42702→M02 03 04 01 43 00 07 78 D9flow = 323, 7
The problem
The cables most security tools cannot see
Pump stations, plant rooms and production lines often run on serial links such as RS485 and Modbus. Network scanners do not see these links, and anything plugged into them is trusted without a password. A device that should not be there, or a command that should not be sent, looks like normal traffic.
iON Bus Monitor sits on the bus, listens, and tells you when something changes.
How it works
How it is designed
- RX-ONLY
Listens, never talks
Designed to be receive-only, so it listens without sending anything onto the cable it is watching.
- BASELINE
Learns what normal looks like
It learns which devices are on the bus, which commands they use and how often they talk, then flags what is new.
- PHY
Spots a swapped device
Aims to detect a rogue or swapped device by its electrical fingerprint: the shape of its signal on the wire.
- AIR-GAPPED
No internet needed
Air-gapped by design: it is designed to run with no internet connection. Updates are signed and applied offline.
- FAIL-OPEN
A person stays in charge
Responses need an operator to approve them. It is designed to fail open, so a fault in the monitor should not stop your process.
- MODBUS
Modbus first, then more
Starts with Modbus RTU and Modbus TCP, the most common languages on industrial cables. DNP3 and other protocols to follow.
Register interest
Want to be an early site?
Tell us about your site and the equipment you run. A rough description is fine. We will reply within two business days.
IN DEVELOPMENT
In development. Pilot sites wanted.
Thanks, you are on the list.
We will reply within two business days.
Also in development
IN DEVELOPMENT
iON Condition Monitor
Our own battery-powered sensor for pumps, motors and fans, designed to learn how each machine normally runs and warn you when that changes. Part of our condition monitoring service.