Services · Canberra and regional NSW
PLC, SCADA and automation services
New control systems, changes, fault finding and upgrades for the pumps, plant, machines and buildings that run your site. PLC, SCADA, telemetry and IoT sensor work for councils, utilities, farms, mining, industry and system integrators, documented and tested so the next engineer can support it.
Good monitoring starts with well-built controls. The same engineer does both, so the data your system makes is data you can use.
Monitoring and anomaly detection01
PLC and HMI programming
A PLC is the small computer that runs a machine or a process, and the HMI is the screen operators use to drive it. New programs, modifications, fault finding and documentation for machines and process plant. Code is structured and commented so the next engineer can pick it up.
- New control programs written from a functional specification
- Modifications and additions to running plant
- Fault finding on intermittent or hard-to-reproduce problems
- HMI screens and alarm handling that operators can read
- As-built documentation and program backups
02
SCADA and telemetry
Know what your remote sites are doing without driving out to them. SCADA brings pump stations, reservoirs, bores, solar and battery sites onto one screen, keeps the history, and raises an alarm that tells operators what is happening before the call-out. Field devices are integrated over Modbus RTU/TCP, DNP3 and MQTT.
- Remote site monitoring for pump stations, bores, solar, battery and substation sites
- Alarm systems with call-out and escalation
- Modbus RTU/TCP, DNP3 and MQTT integration
- Historian and reporting setup
- Cellular, radio and fibre communications
03
Wireless IoT sensors
Battery-powered wireless sensors for sites where cabling or a full RTU does not pay: tanks, bores, creeks, pits and paddocks. Readings arrive on a dashboard or in the systems operators already use, over LoRaWAN, NB-IoT and satellite networks. The network is planned from a radio coverage check before sensors are bought, and each device gets its own keys and credentials instead of the defaults. The work is selection, configuration and integration, not mains electrical installation. Licensed water works that need a LID and telemetry under the NSW metering rules are covered on water meter telemetry.
- Water level, flow, pressure and rainfall monitoring
- Soil moisture, weather and air quality sensing
- LoRaWAN gateways and network servers, or NB-IoT and LTE-M
- Satellite IoT for sites with no mobile coverage
- Data into your SCADA, historian or dashboard over MQTT or Modbus
04
Condition monitoring
Pumps, motors, fans and compressors often show wear in vibration, temperature or current weeks before they stop. Condition monitoring is designed to catch that drift early, so the repair is planned instead of a callout. Each machine is compared against its own learned baseline. There are two ways in: standalone wireless sensors that mount by magnet or stud, run on batteries and send alerts by email, with no control system needed; or drive and PLC data read over Modbus, with alerts in the SCADA or historian operators already watch. What we monitor, how a pilot works and FAQs are on the condition monitoring page.
- Standalone wireless sensors with alerts by email, no control system needed
- Or current, load, run hours and starts read from existing drives and PLCs
- Anomaly models trained on each machine's own history, not generic thresholds
- Alerts by email and dashboard, or in your SCADA or historian with no new hole in the control network
- A fixed-scope pilot on a few critical machines before any ongoing fee
05
Upgrading old control systems
Legacy PLC and HMI migrations: replace end-of-life PLCs and HMIs without a long outage. Programs are converted and tested offline first, then cut over in stages, with a way back at every step.
- Program conversion and clean-up of legacy logic
- Offline testing before cutover
- Staged changeover planned around production
- Updated drawings and documentation
- A rollback plan for every cutover
06
Building automation
Heating, cooling, ventilation and plant from different suppliers often cannot see each other. BMS integration over BACnet and Modbus, so plant and building systems report to one place. The work is programming and integration of controllers, not mechanical or electrical installation.
- BACnet and Modbus gateway configuration
- Point mapping and graphics
- Integrating plant PLCs with the BMS
- Energy and runtime data capture
07
Engineering support for integrators
Spare engineering capacity for system integrators and electrical contractors, offered on a subcontract basis. Overflow programming, commissioning support, functional specifications and documentation, working to your standards and handing over under your name.
- Overflow PLC and SCADA programming
- Commissioning and site support
- Functional specifications
- Documentation and as-built packages
- Work under your project and QA process
08
Water meter telemetry (DQP)
Registered DQP work for licensed non-urban water works that need a meter, a LID or telemetry. Coastal works of 100 ML or more need all three by 1 December 2026 (100 to 15 ML by 1 December 2027). One visit can cover the meter as well as the LID and telemetry; pipe work and mains electrical work stay with other trades. Full scope, pricing approach and FAQs are on the water meter telemetry page.
- Pattern-approved meter installation to the NSW installation test plan
- Local intelligence device (LID) fitted, sealed and tested
- Telemetry reporting to the NSW data acquisition service
- DQP records lodged through the WaterNSW DQP Portal
- Fault finding on a meter or LID that has stopped reporting